The process design of piping is a balance between the size or diameter of the pipe and the pressure drop in the pipe.
For a particular flow rate of fluid, if we select a larger pipe, it gives a lesser pressure drop, but it increases the fixed cost of the pipe. On the other hand, a lower pressure drop means lower power consumption or lower operating cost.
Lower pressure drop may reduce the size of the fluid-moving device (e.g. pump, fan, blower), so it may reduce the fixed cost of the pump.
So, the fixed cost of the pipe increases with diameter while the pumping cost decreases with the diameter of the pipe.
So, here we need to make a balance between pipe diameter and pressure drop in the pipe and find the optimum value of the pipe diameter.
Optimum Pipe Diameter
The optimum pipe diameter depends on the current cost of material, cost of power, and rate of interest at a particular place and at a particular time. It changes with place and time.
Equation below is used to find the optimum diameter of the Carbon Steel Pipe.
This equation is valid for the turbulent flow of an incompressible fluid
Where, doptimum = Optimum pipe size, (mm)
G = Mass flow rate, (kg/s)
ρ = Density of fluid, (kg/m3)
Equation below is used to find the optimum diameter of Stainless Steel Pipe
This equation is valid for the turbulent flow of an incompressible fluid
where, doptimum = Optimum pipe size, (mm)
G = Mass flow rate, (kg/s)
ρ = Density of fluid, (kg/m3)
Standard Pipes
All standard pipes are available from 3 mm (1/8 in) to 600 mm (24 in) size.
Standard pipes are specified with three different diameters,
- Inside Diameter,
- Outside Diameter
- Nominal Diameter.
For standard pipes having a diameter of more than 300 mm (12 in), Nominal Diameters are equal to the actual Outside Diameter. Still, for smaller pipes, there is no relation between Nominal Diameter and Inside Diameter or Outside Diameter.
Wall Thickness of the Standard Pipe
The schedule number indicates it is as per the US standards.
where, psf = Safe working pressure, N/mm2
σs = Safe allowable stress, N/mm2
The thickness of standard pipe increases with increases in schedule number.
Seamless standard pipes do not have welding joints.
Fabricated pipes are fabricated by rolling the plates followed by joining the ends of the plate by welding which are also known as Electric Resistance Welded (ERW) pipes.
Using the following equation the thickness of the pipe, subjected to internal pressure.
where, t = Thickness of pipe, mm
p = Internal design pressure, N/m2
ri = Inside radius of pipe, mm
ro = Outside radius of pipe, mm
σ = Allowable stress of pipe material at design temperature, N/m2
E = Joint efficiency; for seamless standard pipe, E = 1
CA = Corrosion allowance, mm
Suggested Fluid Velocities in Pipe
These are only for approximate calculations of pipe diameter. It can be used for the quick calculation of short-distance pipelines or for estimating pipe size as a starting point for pressure drop calculations.
Table 1: Suggested Fluid Velocities in Pipe
Fluid | Service | Suggested Velocity (m/s) |
---|---|---|
Water | Pump suction line | 0.3 to 1.5 |
Pump discharge line | 2 to 3 | |
Average service | 1 to 2.5 | |
Gravity flow | 0.5 to 1 | |
Steam | 0 to 2 atm g, saturated | 20 to 30 |
2 to 10 atm g, saturated | 30 to 50 | |
Superheated below 10 atm g | 20 to 50 | |
Superheated above 10 atm g | 30 to 75 | |
Vacuum lines | 100 to 125 | |
Air | 0 to 2 atm g | 20 |
> 2 atm g | 30 | |
Ammonia/refrigerant | Liquid | 1.8 |
Gas | 30 | |
Organic liquids and oils | 1.8 to 2 | |
Natural gas | 25 to 35 | |
Chlorine | Liquid | 1.5 |
Gas | 10 to 25 | |
Hydrochloric acid | Liquid (aqueous) | 1.5 |
Gas | 10 | |
Inorganic liquids | 1.2 to 1.8 | |
Gas and vapours | 15 to 30 |
Pressure Drop-in Pipe
Fanning or Darcy equation gives the relation between pressure drop and pipe diameter. It is derived for steady flow in uniform circular pipes running full of liquid under isothermal conditions.
where, Δp = Pressure drop, Pa
L = Length of pipe, m
ṁ = Mass flow rate of fluid, kg/s
ρ = Density of fluid, kg/m3
Di = Pipe inside diameter, m
v = Velocity of fluid, m/s
f = Fanning friction factor
The friction factor is a function of the Reynolds number (Re) and the roughness of the inside surface (ε).
Table 2 – Values of Surface roughness (ε) for various materials
Material | Surface Roughness (ε), mm |
Commercial steel or Wrought iron | 0.045 72 |
Galvanized iron | 0.152 |
Cast iron | 0.259 |
Concrete | 0.305 – 3.05 |
Riveted steel | 0.914 – 9.14 |
Brass, Lead, Glass, Cement, and Bituminous Linings | 0.001 524 |
A plot of Fanning friction factor as a function of Reynolds number (Re) and relative roughness, ε/D, is given as
A more accurate relationship between f and Re for turbulent flow is given by
where, Δp = Pressure drop, kPa
L = Length of pipe, m
Di = Pipe inside diameter, mm
Pressure Drop in Fittings and Valves
In addition to pipes, the piping system contains fittings and valves. These fittings and valves offer additional frictional loss or additional pressure drop. This additional frictional loss of a fitting or of a valve is expressed either as an equivalent straight pipe length (Le) or as a number of velocity heads (K), lost in a pipe of the same size and of the same material.
Equivalent Length of Pipe (Le) for Fittings and Valves
The equivalent length of a valve or of a fitting is the length of a straight pipe of the same size creating the same friction loss as the fitting or the valve in consideration.
Often, Le is expressed in terms of the inside diameter of the pipe.
Then Le = (Le/Di) Di,
where, Di = Inside diameter of the pipe.
Table 3 – Values of Le/Di for valves and fittings
Valve or fitting | Le/Di |
---|---|
Gate valve (fully open) | 7 to 10 |
Gate valve (3/4 closed) | 800 to 1100 |
Gate valve (1/2 closed) | 190 to 290 |
Globe valve (fully open) | 330 to 480 |
Angle valve (fully open) | 165 to 220 |
Plug valve (fully open) | 18 |
90° elbows (standard radius) | 30 |
45° elbows (long radius) | 5.8 |
45° elbows (short radius) | 8.0 |
Return bend (medium radius) | 39 to 56 |
Coupling or union | Negligible |
Tee, straight through | 22 |
Another way of calculating pressure drop through the fittings and valves is the use of factor K.
“Number of velocity heads (K) lost in pipe” for fittings or valves is defined by the equation
where, ΔF = Additional frictional loss, J/kg or N · m/kg
Δp = Additional pressure drop, N/m2
v = Average fluid velocity through the pipe of the same size as valve or fitting, m/s
Table 4 – Values of K for normally used fittings and valves are given in below
Type of fitting or valve | Equivalent number of velocity heads (K) (applicable only for turbulent flow) |
Gate valve (open) | 0.17 |
75% Open | 0.90 |
50% Open | 4.50 |
25% Open | 24.00 |
Globe valve, | |
Bevel seat, Full Open | 06.00 |
50% Open | 09.50 |
Composition seat, Full Open | 06.00 |
50% Open | 08.50 |
Plug disk, Full Open | 09.00 |
75% Open | 13.00 |
50% Open | 36.00 |
25% Open | 112.00 |
Plug valve (open) | 0.4 |
(α = 5°) | 0.05 |
(α = 10°) | 0.29 |
(α = 20°) | 01.56 |
(α = 40°) | 17.30 |
(α = 60°) | 206.00 |
Diaphragm valve, Full Open | 02.30 |
75% Open | 02.60 |
50% Open | 04.30 |
25% Open | 21.00 |
Check valve | |
Swing Check | 02.00 |
Disk Check | 10.00 |
Ball Check | 70.00 |
Angle valve (open) | 02.00 |
Foot valve | 15.00 |
Coupling, Union | 0.04 |
90o elbows (standard) | 0.75 |
90° elbows (long radius) | 0.45 |
90° elbows (Square or miter) | 01.30 |
45o elbows standard | 0.35 |
45o elbows (long radius) | 0.20 |
90° bend | 0.75 |
180° bend (closed return) | 01.50 |
Tee straight through (Standard) | 0.40 |
Tee Used as elbow, entering run, entering branch, Branching flow | 01.00 |
Butterfly valve | |
(α = 5°) | 0.24 |
(α = 10°) | 0.52 |
(α = 20°) | 01.54 |
(α = 40°) | 10.80 |
(α = 60°) | 118.00 |
Check valve (swing type) | 02.00 |
Y or blow off valve, full open | 03.00 |
Water meter, | |
Disk | 07.00 |
Piston | 15.00 |
Rotary (star-shaped disk) | 10.00 |
Turbine-wheel | 06.00 |
References
Sinnott, R. K. (2005). Coulson & Richardson’s CHEMICAL ENGINEERING VOLUME 6 FOURTH EDITION Chemical Engineering Design. Elsevier.
Thakore, S. B. and B. B. I. (2015). Introduction to process engineering and design. McGraw-Hill Education.
Read Also
Know The Basic Difference Between Pipe and Tube
Discover more from All Info ChE
Subscribe to get the latest posts sent to your email.